DESCRIPTION
1. LED
2. emitter
3. DIP switch
4. push button
5. setup adjustment screw
6. mounting screw
7. receiver
8. cable with connector
9. face
TECHNICAL SPECIFICATIONS
Technology
Detection mode
Detection field
Response time
Mounting height
Supply voltage
Mains frequency
Max. current consumption
Standard output:
max. contact voltage
max. contact current
max. switching power
Monitoring input:
max. contact voltage
voltage threshold
Hold time
Reflectivity
Temperature range
Degree of protection
Dimensions
Housing material
Cable length (main cable)
Norm conformity
75.5390.02 SMART FOCUS 20191002
2
1
3
active infrared
presence detection by distance measurement
1
2
" × 2
3
" (at 7' mounting height)
5
4
64 ms
2 – 10'
12 – 24 VAC/VDC -5% / +10%
50 – 60 Hz
120mA @ 24 VAC / 80mA @ 24 VDC
relay (free of potential contact)
42 VAC/VDC
1A (resistive)
30W (DC) / 42 VA (AC)
1 optocoupler (free of potential contact)
30 V
high state: > 10 V
low state: < 1 V
0.5 s
min. 10% at IR-wavelength of 850nm
-13 – 131 °F (-25 – 55 °C)
0 – 95% rel. humidity, non-condensing
IP53
5 3/4" (L) x 1 3/5" (H) x 2" (D)
ABS (black)
8'
IEC 61000-6-2; IEC 61000-6-3; ISO 13849-1 Performance Level «c» CAT. 2
(under the condition that the door control system monitors the sensor at least once per door cycle)
Specifications are subject to change without prior notice.
All values measured in specific conditions.
SMART FOCUS
Active infrared safety sensor for automatic doors
4
5
9
7
6
8
Page 1 of 4

Advertisement

loading

Summary of Contents for BEA Smart Focus

  • Page 1 IEC 61000-6-2; IEC 61000-6-3; ISO 13849-1 Performance Level «c» CAT. 2 (under the condition that the door control system monitors the sensor at least once per door cycle) Specifications are subject to change without prior notice. All values measured in specific conditions. 75.5390.02 SMART FOCUS 20191002 Page 1 of 4...
  • Page 2 If the LED continues to flash, the sensor The sensor can also be installed on the surface by using the must be adjusted (see next page). surface mount accessory (sold separately). Page 2 of 4 75.5390.02 SMART FOCUS 20191002...
  • Page 3 Use F2 in any of the following conditions: • monitoring input = active high • monitoring input = active low • no monitoring required When finished, confirm DIP changes with a long push of the push button. 75.5390.02 SMART FOCUS 20191002 Page 3 of 4...
  • Page 4 BEA, Inc. does not guarantee any use of the sensor outside of its intended purpose. BEA, Inc. strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and factory-trained for the type of door/gate system.