Removal Of Swing Motors (Pattern 1) - Daikin FTKS09HV2S Service Manual

Removal procedure, 2.0/2.5/3.5/4.6 kw class, 9000/12000 btu/h class
Table of Contents

Advertisement

Removal of Swing Motors (Pattern 1)

8. Removal of Swing Motors (Pattern 1)
Procedure
Step
1. Remove the swing motor
for vertical blades.
1
Lift the indoor unit with
a wooden base.
Remove the screw
2
behind the drain hose,
and disconnect the
drain hose.
Remove the screw at
3
the rear, and remove
the screws on the right
and the left side of the
swing motors for
horizontal blades.
24
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Drain hose
Swing motor for
horizontal blades
(R10323)
(R10329)
(R13748)
Si041137
Points
Removal Procedure

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents