Download Print this page

Frymaster LOV BIGL30 Series Installation, Operation And Maintenance Manual page 36

Gas fryer
Hide thumbs Also See for LOV BIGL30 Series:

Advertisement

Left Viewing
Port is Behind
Motor
(NOTE: Blower
shield omitted
for clarity.)
The air/gas mixture is properly adjusted when the burner manifold pressure is in accordance with the
applicable table on page 2-7 and the burners display a bright orange-red glow. If a blue flame is
observed, or if there are dark spots on a burner face, the air/gas mixture requires adjustment.
On the side of the blower housing opposite the motor is a plate with one or two locking nuts. Loo-
sen the nut(s) enough to allow the plate to be moved, then adjust the position of the plate to open or
close the air intake opening until a bright orange-red glow is obtained. Carefully hold the plate in
position and tighten the locking nut(s).
TYPICAL BLOWER ASSEMBLY
5.6
SEMI-ANNUAL CHECKS AND SERVICE
5.6.1 Clean Gas Valve Vent Tube
NOTE:
This procedure is not required for fryers configured for export to CE
countries.
1. Set the fryer power switch and the gas valve to the OFF position.
2. Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened
for ease in removal.
Figure 4
SOME CE BLOWER ASSEMBLIES
MAY BE CONFIGURED THIS WAY
5-6
Right
Viewing
Port

Hide quick links:

Advertisement

loading