Eyebolt
The display has holes for attaching eyebolts (M10).
When installing, use them to suspend the display.
Use the eyebolt only for temporary suspension or
movement for installation. This cannot be used for
permanent hanging installation.
Eyebolt (commercially available) mounting positions
1
When attaching the eyebolt, remove
the eyebolt cap from the eyebolt
mounting position (two locations),
and leave the flat washer (black) as it
is.
Flat washer (black)
2
Attach the eyebolt with the flat washer
(black) left as it is.
Flat washer (black)
16
English
Eyebolt cap
Eyebolt
3
After removing the eyebolt, tighten
the eyebolt cap with the flat washer
(black) left as it is.
Flat washer (black)
Note
●
Installation should be performed by an installation
professional.
●
Do not suspend using only 1 eyebolt.
●
Use commercially sold M10 eyebolts with a shank
length of 12 mm to 40 mm that satisfies the load
condition of product quality.
●
Use ISO 3266 standard eyebolts. Also use ISO
standard members (wire, etc.) for hanging.
●
The hanging angle should be 60° or more.
●
After installation, remove the eyebolts, and close the
holes using the eyebolt caps removed when attaching
the eyebolts.
φ 41 mm
or less
12 mm to
40 mm
60° or more
Eyebolt cap