POSSIBLE REMOTE CONTROL SETTINGS (motion sensing)
FIELD SIZE
(SENSITIVITY)
HOLD-OPEN TIME
DETECTION MODE
DETECTION FILTER
(REJECTION MODE)
Detection of ALL TARGETS
(pedestrians, vehicles and parallel traffic are detected)
1 Detection of all kind of Targets in Motion
2 Detection of all kind of Targets in Motion +
Interference Immunity
OUTPUT
CONFIGURATION
DOOR EXAMPLE
First Line
Last Line
AIR PATTERN SIZE AT 15
Approximate default AIR pattern size using a 15º sensor tilt angle. The higher the mounting height the larger the AIR
pattern.

Mounting Height

11.5 ft
Page 6 of 9
XXS
XS
0.5 s
1 s
bi
1
PRESENCE RELAY
0 - 6: ALL MODES
ACTIVATION RELAY
0: STANDARD MODE
1: PULSE ON ENTRY
2: PULSE ON EXIT
3: PULSE ON ENTRY FIRST / LAST LINE
(See Example to the Left)
4: PULSE ON EXIT FIRST / LAST LINE
(See Example to the Left)
5: REMAINS ACTIVE UNTIL PRESENCE
ZON E IS CLEARED (Regardless of Motion)
6: REMAINS ACTIVE UNTIL PRESENCE
ZONE IS CLEARED (Regardless of Motion)
SENSOR ANGLE
O
Width *
5 ft
8 ft
10 ft
7 ft
7.5 ft
8.5 ft
13 ft
16 ft
10 ft
S
>
>
2 s
3 s
4 s
5 s
uni
uni
AWAY
2
3
4
Detection only of VEHICLES MOVING TOWARDS THE SENSOR
(pedestrians and parallel traffic are not detected + immunity filter)
3
Low 'Pedestrian/Parallel traffic' Rejection + Interference
Immunity
4
Medium 'Pedestrian/Parallel traffic' Rejection + Interference
Immunity
5
High 'Pedestrian/Parallel traffic' Rejection + Interference
Immunity
6
Extra High 'Pedestrian/Parallel traffic' Rejection +
Interference Immunity
Activates when object is in presence zone.
Activates when motion detected.
Activates if object motion is detected and then object
enters presence zone.
Activates if object motion is detected and then object exits
presence zone.
Activates if object motion is detected and then object
enters presence zone (first or last line).
Activates if object motion is detected and then object exits
presence zone (first or last line).
Activates when motion is detected and remains active until
the presence zone is cleared.
Activates when motion is detected and AIR is detected and
remains active until the presence zone is cleared.
Depth *
5 ft
7 ft
7.5 ft
8.5 ft
*
10 ft
>
>
L
XL
6 s
7 s
8 s
bi = two-way detection
uni = one-way detection towards sensor
uni AWAY = one-way detection away from sensor
5
6
IS40 / IS40XL
IS40 / IS40XL
Maximum Mounting Height
IS40XL
IS40
Dimensions are approximate.
75.5695.07 IS40 IS40XL 20170313
XXL
9 s
LED
Red
LED
Green
11.5 ft
16 ft

Advertisement