Download Print this page

Mounting And Wiring - BEA FALCON XL User Manual

Activation sensor for automatic industrial doors

Advertisement

6
MOUNTING & WIRING
1
1 1/2
1 9/16
1 1/16
1 1/16
1 1/16
4 1/8
Remove the bracket from
the sensor. Drill 2 holes
accordingly. Afix the bracket
firmly.
7
DETECTION FIELD ADJUSTMENTS
1
Adjust the angle of the sensor to position the detection field.
FALCON
Mounting height: 16 ft
ft.
6.5
3
0
All detection field dimensions were measured in optimal conditions and with field size value 9.
8
DETECTION FILTER - PEDESTRIAN REJECTION - VEHICLE DETECTION
Choose the right detection filter for your application with the remote control or the push buttons:
Detection of all targets
(pedestrians and parallel traffic are detected)
1-6
1 = no specific filter
2 = filter against disturbances
(recommended in case of vibrations,
rain etc.)
75.5678.04 20111104
2
1 1/4
1/2
Position the sensor on the
bracket and fasten the screws
firmly.
CEILING
WALL
3
6.5
FALCON
Mounting height: 11.5 ft
ft.
6.5
3
0
3
6.5
Detection only of vehicles moving towards the sensor*
(pedestrians and parallel traffic are not detected + disturbances are filtered)
Value recommendations according to angle and height:
23 ft 16 ft 11.5 ft
°
15
3
3
3
°
30
4
4
4
°
45
5
5
5
°
> 45
6
6
6
* The vehicle detection filter increases the response time of the sensor.
3
Red
12-24 V
Black
AC-DC
White
COM
Green
NO
Yellow
NC
Connect the wires to the door
controller. Choose between
NO and NC contact.
2
0-9
Adjust the field size with the remote
control or the push buttons.
FALCON XL
Mounting height: 8 ft
ft.
6.5
3
0
3
Always check if the chosen value is
8 ft
optimal for the application. The
3
object approach angle, speed, size
4
4
and nature can influence it's
5
detection.
XL
6.5
Page 3 of 5

Advertisement

loading

This manual is also suitable for:

Falcon