Parameter reference
8.6 Setup (2.)
Discrete input 1 scaled state (2.9.2.3.)
Shows the current value of the discrete input after any scaling is applied. Read only.
Index
Modes
Readings are updated continuously even in PROGRAM mode. The value signals a level
override event.
Discrete input 2 scaled state (2.9.2.4.)
Shows the current value of the discrete input after any scaling is applied. Read only.
Index
Modes
Readings are updated continuously even in PROGRAM mode. The value signals a level
override event.
8.6.10
Other Control (2.10.)
Sets other relay control features.
8.6.10.1
External totalizer (2.10.1.)
Tracks the volume of material that passes through a system. The external totalizer controls a
relay to signal an external totalizing device. The relay toggles ON and OFF at a rate set by
the parameters below.
8.6.10.2
Transducer selector (2.10.1.1.)
Sets the transducer index for all parameters applicable to this submenu. The parameters will
only affect the relays set to Relay Function (2.8.1.4.) (Page 195) = Totalizer.
210
Discrete input
Active
Inactive
Discrete input
Active
Inactive
HydroRanger 200 HMI
Operating Instructions, 06/2018, A5E36281317-AC