4.2.5

SCALANCE X208 Power Supply and Signaling Contact

Power Supply
The power supply is connected using a 4-pin plug-in terminal block. The power supply can
be connected redundantly. Both inputs are isolated. There is no distribution of load. When a
redundant power supply is used, the power supply unit with the higher output voltage
supplies the SCALANCE X208 alone. The power supply is connected over a high resistance
with the enclosure to allow an ungrounded set up.
Figure 4-5
Warning
The SCALANCE X208 is designed for operation with safety extra-low voltage. This means
that only safety extra-low voltages (SELV) complying with IEC950/EN60950/ VDE0805 can
be connected to the power supply terminals.
The power supply unit to supply the SCALANCE X208 must comply with NEC Class 2
(voltage range 18 - 32 V, current requirement 350 mA)
If the device is connected to a redundant power supply (two separate power supplies), both
must meet these requirements.
The signaling contact can be subjected to a maximum load of 100 mA (safety extra-low
voltage (SELV), DC 24 V).
Never connect the SCALANCE X208 to AC voltage or DC voltage higher than 32 V DC.
Signaling Contact
The signaling contact is connected to a 2-pin plug-in terminal block. The signaling contact
(relay contact) is a floating switch with which error/fault states can be signaled by breaking
the contact.