Siemens SIMATIC PC 670 Equipment Manual page 95

Computing unit
Hide thumbs Also See for SIMATIC PC 670:
Table of Contents

Advertisement

Release 04/02
Primary Master, Primary Slave, Secondary Master, Secondary Slave
The system jumps to the following submenu when you select this type of menu
field:
Figure 5-3
Field Type
The parameters you can select here are normally stored on your IDE drive. The
'Auto' setting in the Type field means that these values are automatically read
from the drive and written into memory (Autodetect).
If Type is selected for a drive that cannot be detected, a timer times out in
approximately 1 minute and the entries remain unchanged. You should always
check that the interfaces for which you select 'Auto' are in fact connected to
drives.
Select "User" if you want to define the hard-disk type yourself, in which case
remember that you also have to set the other fields, including Cylinder, Heads,
Sectors/Track and WritePrecomp, to the correct values for the type of hard disk in
question.
Panel PC 670 Computing Unit, Equipment Manual
PhoenixBIOS Setup Utility
Main
Primary Master [20496 MB]
Type:
[
Auto
LBA Format
Total Sectors:
40031712
Maximum Capacity:
20496 MB
Multi-Sector Transfers:
[16 Sectors]
[Enabled]
LBA Mode Control:
32 Bit I/O:
[Enabled]
Transfer Mode:
[FPIO 4 / DMA 2]
Ultra DMA Mode:
[Disabled]
Help
Select Item
F1
ESC
Exit
Select Menu
Primary Master
Configuring the Computing Unit in BIOS Setup
Item Specific Help
[Auto] (recommended)
]
Autotypes installed
IDE-devices
[USER]
Enter parameters of
IDE-devices installed
at this connection
+ / –
Change Values
Enter
Select
Sub-Menu
F9
Setup Defaults
F10
Save and Exit
5-7