Download Print this page

Cable & Connector; How To Connect The Connectors; Block Diagram - Contec AIO-121602AL-PCI User Manual

12-bits analog i/o board (low gain) for pci

Advertisement

Data acquisition VI library for LabVIEW VI-DAQ
(Available for downloading (free of charge) from the
CONTEC web site.)
This is a VI library to use in National Instruments LabVIEW.
VI-DAQ is created with a function form similar to that of
LabVIEW's Data Acquisition VI, allowing you to use various
devices without complicated settings.
See http://www.contec.com/vidaq/ for details and download of
VI-DAQ.
Cable & Connector
Cable(Option)
Flat Cable with Two 37-pin D- SUB Connectors
Shielded Cable with Two 37-pin D- SUB Connectors
Flat Cable with One 37-pin D- SUB Connector
Shielded Cable with One 37-pin D- SUB Connector
30-pin Pinhead Connector to 37-pin D-SUB Connector
Connector (Option)
D-SUB37P Male Connector Set (5pieses)
*1
It is necessary for the connection of the digital I/O signal, the counter signal, and the
control signal.
Accessories
Accessories (Option)
Screw Terminal (M3 x 37P)
Screw Terminal (M3.5 x 37P)
General Purpose Terminal
Screw Terminal
*1
PCB37P or PCB37PS optional cable is required separately.
*2
"Spring-up" type terminal is used to prevent terminal screws from falling off.
*3
A DT/E2 and PCB37P or PCB37PS optional cable is required separately.
*
Check the CONTEC's Web site for more information on these options.

Block Diagram

8 single-end
2 Analog Outputs
Analog Inputs
DA
Multiplexer
Converter
OP
Amplifer
A/D
Converter
DC/DC
converter
AIO-121602AL-PCI
: PCB37P-1.5 (1.5m)
: PCB37PS-0.5P (0.5m)
: PCB37PS-1.5P (1.5m)
: PCA37P-1.5 (1.5m)
: PCA37PS-0.5P (0.5m)
: PCA37PS-1.5P (1.5m)
: DT/B2 (0.5m) *1
: CN5-D37M
: EPD-37A *1*2*3
: EPD-37 *1*3
: DTP-3A *1*3
: DTP-4A *1*3
4 Digital Input / 4 Digital Output
External Trigger Inputs
Counter Input / Output
CN1
DA
Converter
FPGA
PCI Bus

How to connect the connectors

Connector shape
The on-board interface connector (CN1 and CN2) is used when
connecting this product and the external devices.
Interface connector (CN1)
37
36
Interface connector (CN2)
21
20
CN2
A15 A14 A13
B15 B14 B13
*
Please refer to page 3 for more information on the supported cable and accessories.
Connector Pin Assignment
Pin Assignments of Interface Connector
Digital Ground
37
Analog Ground
36
Analog Ground
35
Analog Ground
34
Analog Ground
33
Analog Ground
32
Analog Ground
31
Analog Ground
30
Analog Ground
29
Analog Ground
28
Analog Ground
27
Analog Ground
26
Analog Ground
25
Analog Ground
24
Analog Ground
23
Analog Ground
22
Analog Ground
21
Analog Ground
20
Analog Input 0
Analog input signal. The numbers correspond to channel numbers.
- Analog Input 15
Analog Output 0
Analog grounds for identically numbered analog input signals.
- Analog Output 1
Analog Ground
Common analog ground for analog I/O signals.
Digital Ground
Common digital ground for digital I/O signals, external trigger inputs,
external sampling clock inputs, and counter I/O signals.
+5VDC
5V DC from PC
CAUTION
analog or digital ground.
Neither connect outputs to each other. Doing either can
result in a fault.
If analog and digital ground are shorted together, noise on
the digital signals may affect the analog signals.
Accordingly, analog and digital ground should be separated.
Leave "Reserved" pins unconnected. Connecting these
pins may cause a fault in the board.
Pin Assignments of Interface Connector CN2
CN2
Digital Ground
DGND
B15
A15
Digital Ground
DGND
B14
A14
Digital Ground
DGND
B13
A13
Digital Ground
DGND
B12
A12
Digital Ground
DGND
B11
A11
Digital Ground
DGND
B10
A10
Ground
Reserved
B9
A9
Digital Ground
DGND
B8
A8
Digital Ground
DGND
B7
A7
Digital Ground
DGND
B6
A6
Digital Ground
DGND
B5
A5
B4
A4
Digital Output 03
DO 03
Digital Output 02
DO 02
B3
A3
Digital Output 01
DO 01
B2
A2
Digital Output 00
DO-00
B1
A1
Ver.1.02
- Connector used
37-pin D-SUB, female connector
19
DCLC-J37SAF-20L9E (mfd. by JAE)
18
Thumb screw : UNC#4-40(inch screw)
- Applicable connectors
17JE-23370-02(D8C)-CG (mfd. by DDK, Male)
FDCD-37P(55) (mfd. by HIROSE, Male)
2
DC-37P-NR (mfd. by JAE, Male)
1
CN1
A3 A2 A1
B3 B2 B1
- Connector used
PS-30PE-D4T1PN1(made by JAE)
or equivalent to it
- Applicable connector
PS-30SEN-D4P1-1C (made by JAE)
CN1
19
+5V DC from PC
18
Analog Output 01
17
Analog Output 00
16
Analog Input 15
15
Analog Input 7
14
Analog Input 14
13
Analog Input 6
12
Analog Input 13
11
Analog Input 5
10
Analog Input 12
9
Analog Input 4
8
Analog Input 11
7
Analog Input 3
6
Analog Input 10
5
Analog Input 2
4
Analog Input 9
3
Analog Input 1
2
Analog Input 8
1
Analog Input 0
AO External Start Trigger Input
AO START
AO External Stot Trigger Input
AO STOP
AO External Sampling Clock Input
AO EXCLK
AI External Start Trigger Input
AI START
AI STOP
AI External Stot Trigger Input
AI External Sampling Clock Input
AI EXCLK
CNT GATE Counter Gate Control Input
CNT GATE
Counter UP Clock Input CNT UPCLK
CNT UPCLK
Counter Output
CNT OUT
5V
Vcc
DGND
Digital Ground
Digital Input 03
DI 03
Digital Input 02
DI 02
Digital Input 01
DI 01
Digital Input 00
DI-00
3

Advertisement