Hussmann Q3-DV Installation & Operation Manual page 6

Deli service case, vertical glass
Table of Contents

Advertisement

Installation (cont'd)
Transport
Q3-DV Lifting and
Instructions
1. The Q3-DV can be lifted by a forklift at typical lift-
ing points.
2. Ensure lower body panels are removed before
lifting with a forklift. Serious damage will occur if
the body panels are not removed. (Shipped loose
from factory)
3. Make sure that fork spacing and width will not
damage drain or come in contact with piping, or
electrical lines
4. Be sure that the forks are long enough to sup-
port beyond the center of the case but not dam-
age near components. Check for proper balance
before moving. A minimum fork length of 36" is
recommended for 68" wide cases
Q3-DV Drain Location
Drain
5. The Q3-DV merchandiser can be raised at one
end underneath the deck with a forklift or J-Bar if
forklift is not accesible to allow the placement of
rollers or dollies.
6. Evenly support the entire base structure on rollers
or dollies before attempting to move. Each Base
Leg must have its own dollie to properly support
the case.
WARNING
Improper placement of forks may damage
drainage piping. Use a spotter when placing
forks. Make sure that piping will not be dam-
aged. Use J-Bars or Jacks if forks cannot be
used safely
Lifting Points are typical and dependent upon size of
case and refrigeration application, drainage confi gu-
rations will call for altercations in Lifting Zones.
Below are the following drainage confi gurations and
lifting should be altered to the expected model.