Hussmann Q3-DV Installation & Operation Manual page 27

Deli service case, vertical glass
Table of Contents

Advertisement

CIRCUIT #1
LOADING
120V
L1
4. 2
L2
L3
CANOPY
CIRCUIT #2
LOADING
120V
L1
0. 2 8
L2
L3
LIGHT SWITCH
TIPPETTE
125-01-0311
L
L1 N
~120 VAC - 60 Hz.
MCA= 0. 7 0A
MOP= 15A
NOTES:
CASE MUST BE GROUNDED
RJ-45 NETWORK JACK
125-01-0202
SHELVES
LIGHT CIRCUIT
. 5 6A 60W @ 120V
AIR SWEEP FAN
(2) 0404551
15W . 2 0A @120VAC
M
M
M
BUNDLE
BROWN
BUNDLE
L1
N
ORANGE
~120 VAC - 60 Hz.
MCA= 1.1A
MOP= 15A
CIRCUIT #3
GFCI DUPLEX
125-01-3178
BUNDLE
YELLOW
ALL SINGLE
RECEPTACLES TO BE
INCOMING POWER
TIED TO DUPLEX GFCI
~120 VAC -60 Hz
RECEPTACLE
AIR SWEEP HEATER
300W 2. 6 1A @ 115 VAC
125-01-1302
M
EVAP FAN MOTOR
(4) 0477653
4W . 1 2A @120VAC
SWITCH
125-01-0311
M
M
L
BUNDLE
PURPLE
L1
N
~120 VAC - 60 Hz.
MCA= 3. 3 A
MATERIAL - N/A
MOP= 15A
DATE DRAWN - 6-4-15
DRAWN BY -CRAIG BOOREY
REVIEWED BY -CRAIG BOOREY
APPROVED BY - CRAIG BOOREY
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
DECIMALS . X X
REVISION HISTORY
REV
ECN
DATE
REVISION DESCRIPTION
A
987576
2015/06/04
RELEASED TO PRODUCTION
B ECN-CAP-0001777 2016/05/13
CHANGED AIR SWEEP HEATER
CIRCUIT #2
SOLENOID WIRING PER COIL
SUCTION SOLENOID
. 1 4A @ 120VAC
T-STAT
1H66770550
SENSOR
BUNDLE
WHITE/BLACK
N L1
~120 VAC - 60 Hz
DIAGRAM-Q3-DV-8-R
ECN# - 987576
REF -
W/DIGITAL T-STAT
SHEET 1 OF 1
THIRD
2H14596
u
. 0 3, . X XX
u
. 0 10
ANGLE
ANGLES
2
u
v
PROJECTION
REV BY CHKD BY APPR BY
CB
CB
CB
CB
CB
CB
B