DSF Hardware Notes
If NEM hardware is replaced or needs adjustment. Be sure that the following notes are followed.
1) NEM glass hardware must be attached to front of merchandiser with 1/4"- 20 taper head machine screws
2) Loctite 242 thread locker must be applied to the threads of all screws used to attach the glass hardware to the
merchandiser.
Installing and Adjusting DSF Glass
STEP 1:
PULL OUT HARDWARE ARM
TO OUTER MOST POSITION
Installation (Cont'd)
• Glass is Heavy and can cause serious injury.
• Professional installation recommended.
• Have an assistant hold glass while adjusting
glass and/or hardware to prevent breakage!
LOOSEN ALL CLAMP
BOLTS EVENLY UNTIL
GLASS IS LOOSE
STEP 2:
18
STEP 3:
PULL GLASS
FROM CLAMP