Viessmann VITODENS 200-W Type B2HA Technical Manual page 97

Wall mounted gas condensing boiler
Hide thumbs Also See for VITODENS 200-W Type B2HA:
Table of Contents

Advertisement

Control units
(cont.)
On-site requirements
■ DSL router with free LAN socket and dynamic IP addressing
(DHCP)
■ Internet connection with flat rate data (without time or volume
restrictions)
■ LON communication module must be installed in the Vitotronic.
Note
For more information, see www.vitocom.info.
Standard delivery
■ Vitocom 300, type LAN3 with LAN socket
– Mounting rail installation TS35 to EN 50022, 35 x 15 and
35 x 7.5
– 2 digital inputs
– 1 digital output
– 1 relay output
– 1 M BUS interface
– 1 EM interface
– 2 LON connections
■ LAN cable, RJ 45, 2 m long
■ LON communication module
■ LON cable, RJ 45 – RJ 45, 7 m long, for data exchange between
the Vitotronic control unit and the Vitocom 300
■ Power supply unit for top-hat rail, mounting rail installation TS35 to
EN 50022, 35 x 15 and 35 x 7.5
■ Vitodata 100 fault management for a duration of 3 years
Note
For standard delivery in packs with Vitocom, see pricelist.
Accessories
Accessories
Wall mounting enclosure for installation of the
Vitocom 300 and accessories if no control panel or
electrical distribution panel is available.
2 rows
3 rows
EM301 extension module
– Mounting rail installation TS35 to EN 50022,
35 x 15 and 35 x 7.5.
– 8 analogue inputs:
– 0 − 10 V
– 4 − 20 mA
– Viessmann temperature sensors NTC 10 kΩ,
NTC 20 kΩ, Ni500 or Pt500
– Pulse counter
– 8 digital inputs:
– For hooking up signals via floating contacts
– 2-pole
– Breaking capacity of the external contact 24 V ,
7 mA
– With LED indicator
– N/C or N/O contact
– N/C or N/O alarm contact
– Pulse counter
– 2 digital outputs:
– Floating relay contacts
– 3-pole changeover contact
– Max. 2 A, 230 V~
– With LED indicator
Max. 3 x EM301 extension modules per Vitocom 300
Uninterrupted power supply module (UPS)
Mounting rail installation TS35 to EN 50022, 35 x 15
and 35 x 7.5
VITODENS 200-W
Accessories
Additional rechargeable battery pack for UPS
– Mounting rail installation TS35 to EN 50022,
35 x 15 and 35 x 7.5
– Recommended with 1 Vitocom 300 and 1 exten-
sion module where all inputs are allocated
– Required with 1 or more Vitocom 300 and 2 exten-
sion modules
Connecting cable extension
Installation spacing 7 to 14 m
– 1 connecting cable (7 m long)
and
1 LON coupling RJ 45
Installation spacing 14 to 900 m with plug-in con-
nector
– 2 LON plug-in connectors (RJ 45)
and
– 2-core cable, CAT5, screened, solid wire,
AWG 26-22, 0.13 to 0.32 mm
4.5 to 8 mm
or
2-core cable, CAT5, screened, stranded wire,
AWG 26-22, 0.14 to 0.36 mm
4.5 to 8 mm.
Installation spacing 14 to 900 m with socket
– 2 connecting cables (7 m long)
and
– 2 LON sockets RJ 45, CAT6
– 2-core cable, CAT5, screened
or
JY(St) Y 2 x 2 x 0.8
Vitocom 300 specification (standard delivery)
Part no.
7143434
7143435
9 0
1 0
Z012117
Specification
Rated voltage
Rated current
Rated output
Protection class
IP rating
Mode of operation
Permissible ambient temperature
– Operation
– Storage and transport
On-site connections
– 2 digital inputs DI1 and
DI2
– 1 digital output DO
7143432
– 1 M BUS interface
– 1 EM interface
2
, external diameter
2
, external diameter
5
24 V
710 mA
17 W
II to EN 61140
IP 30 to EN 60529; ensure through de-
sign/installation
Type 1B to EN 60730- 1
0 to +50 °C
Installation in living spaces or installa-
tion rooms (standard ambient condi-
tions)
−20 to +85 °C
Floating contacts, contact breaking ca-
pacity 24 V , 7 mA, for monitoring ad-
ditional devices and third party systems,
with LED indicator
Relay, contact breaking capacity 24 V ,
max. 2 A, changeover contact
For connecting heat meters with M BUS
interface to EN 1434-3
For connecting up to 3 x EM301 exten-
sion modules, with LED indicator
VIESMANN
Part no.
7143436
7143495
and
7143496
7199251
and
On site
7143495
and
7171784
On site
5
97

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents