Viessmann VITODENS 200-W Type B2HA Technical Manual page 18

Wall mounted gas condensing boiler
Hide thumbs Also See for VITODENS 200-W Type B2HA:
Table of Contents

Advertisement

Vitodens 200-W
With heating circuit connection set for combination with system separation or heating water buffer cylinder
480
1
F
200
A
D
B
C
160
160
A Safety valve
B Connection for expansion vessel G 1 (male thread)
C Boiler flow G 1½ (male thread)
D Gas connection Rp 1
E Boiler return G 1½ (male thread)
F Cable entry area at the back
Note
■ The heating circuit connection set must be ordered separately.
■ Lay all required supply cables on site and route them into the
boiler in the specified area.
Variable speed high efficiency circulation pump in the heating circuit connection set (accessories)
The highly efficient circulation pump uses significantly less power
compared to conventional pumps.
Matching the pump rate of the circulation pump to the individual sys-
tem conditions reduces the power consumption of the heating sys-
tem.
VIESMANN
18
(cont.)
G
E
236
N
100
530
O
G Connection sets (accessories)
H Without connection set (accessories)
K Recommended dimension (single boiler system)
L Recommended dimension (multi boiler system)
M With connection set (accessories)
N Condensate drain
O Top edge, finished floor
Circulation pump VI PARA 25/1-12
Rated voltage
V~
Power consumption
– max.
W
– min.
W
230
310
16