Vitodens 200-W
Note
If the residual head of the circulation pump available as an acces-
sory is insufficient to overcome the following system pressure drop
values, install an additional, external circulation pump on site. In this
1
case, either the heating circuit connection with integral low loss
header, a system separation or a heating water buffer cylinder must
be used.
Pressure drop on the heating water side
For sizing a circulation pump (accessories or on-site provision)
600
60
500
50
400
40
300
30
200
20
100
10
0
0
0
Flow rate in l/h
Note
When the heating circuit pump and circulation pump for cylinder
heating are operated in parallel mode (no DHW priority control), we
recommend the installation of a DHW cylinder in the secondary side
(downstream of the system separation or the heating water buffer
cylinder) of the heating system.
VIESMANN
20
(cont.)
1000
2000
3000
4000
5000
6000
7000
VITODENS 200-W