Olivetti PF-720 Service Manual page 26

Option copier
Table of Contents

Advertisement

Maintenance
item No.
U034
When [LSUOUT TOP B/W] is selected.
Display
LSUOUT TOP
MPT (L) B/W
LSUOUT TOP
CAS (L) B/W
LSUOUT TOP
DUP (L) B/W
LSUOUT TOP
MPT (S) B/W
LSUOUT TOP
CAS (S) B/W
LSUOUT TOP
DUP (S) B/W
Large size: 218 mm or more in width of paper.
3. Press the system menu key.
4. Press the start key to output a test pattern.
5. Press the system menu key.
6. Change the setting value using the +/- or numeric keys.
For output example 1, increase the value. For output example 2, decrease the value.
Leading edge
registration
(20 ± 1.5 mm)
7. Press the start key. The value is set.
Remark
When changing the setting value of [Large] each item is modified, equal to amount of the value which is
changed adds also the value of [Small] each item and is pulled.
Caution
Check the copy image after the adjustment. If the image is still incorrect, perform the following adjustments in
maintenance mode.
U034
Y112020-4
Description
Paper feed from MP tray
(when large size paper is used)
Paper feed from cassette
(when large size paper is used)
Duplex mode (second)
(when large size paper is used)
Paper feed from MP tray
(when small size paper is used)
Paper feed from cassette
(when small size paper is used)
Duplex mode (second)
(when small size paper is used)
Correct image
U066
(See the service manual
for the machine.)
Service Manual
Description
Setting
range
-3.0 to 3.0
-3.0 to 3.0
-3.0 to 3.0
-3.0 to 3.0
-3.0 to 3.0
-3.0 to 3.0
Output
example 1
example 2
Figure 1-3-1
U071
(See the service manual
for the machine.)
Default
Change in
setting
value per step
0
0.1 mm
0
0.1 mm
0
0.1 mm
0
0.1 mm
0
0.1 mm
0
0.1 mm
Output
3LM-1
1-3-5

Advertisement