INSTALLATION GENERAL
4. Since the Constellation Flame Fire is a decorative effect appliance, the space in which the unit
is installed must have adequate fixed ventilation compliant with the requirements of AS 5601.
For Decorative Gas Log Fires this requires that one or more openings with a combined free
ventilation area of not less than 314 cm² (31400 mm²) shall be provided for each appliance.
Notes regarding ventilation: *
The opening may be provided by any of the following options, provided that there is a ventilation path to
outside that is unobstructed by building material or insulation:
i.
a) Directly through an outside wall (preferred option).
b) Through to an outside wall but offset.
c) Into a cavity ventilated to outside.
d) Into an underfloor space ventilated to outside.
e) Into a roof space ventilated to outside.
5. The Constellation Flame Fire comes
supplied with power cord and 3 pin plug
passing through the insulating bush in the
lower right hand side of the rear panel as
shown. This is suitable for plugging into a
10A earthed power point if this power
point is accessible to the end user with
the appliance in the installed condition.
This power point must not be located
above the appliance. If the power supply
is to be concealed, the appliance can be
directly
hard wired by an Authorised
electrical tradesperson with an isolating
switch accessible to the end user with the
appliance in the installed condition. Refer
to AS 3000 and AS 5601 for details.
6. The Constellation Flame Fire must not
be installed where curtains or other
combustible materials could come into
contact with it. In some cases, curtains
may need restraining.
See diagram for minimum clearances
required.

MANTLES

A mantle is allowable providing that it conforms
to the dimensions and clearances shown.
* Derived from AS 5601 - 2005.
Rinnai Australia
3 0 0 m
m
1 0 0 0
- 14 -
Constellation Model 800/1000 - Installation Manual
INSULATING BUSH
POWER CORD
3 0 0 m
m
3 0 0 m
m
m m

Hide quick links: