Keep Components A and B Separate

Keep Components A and
B Separate
CAUTION
To prevent cross-contamination of the equipment's
wetted parts, never interchange component A (isocy-
anate) and component B (resin) parts.
Foam Resins with 245 fa
Blowing Agents
New foam blowing agents will froth at temperatures
above 90°F (33°C) when not under pressure, especially
if agitated. To reduce frothing, minimize preheating in a
circulation system.
8

Changing Materials

When changing materials, flush the equipment mul-
tiple times to ensure it is thoroughly clean.
Always clean the fluid inlet strainers after flushing,
see page 31.
Check with your material manufacturer for chemical
compatibility.
Most materials use ISO on the A side, but some use
ISO on the B side.
Epoxies often have amines on the B (hardener)
side. Polyureas often have amines on the B (resin)
side.