4.2 COMMANDS AND PARAMETERS

4.2.1 Commands

4.2.1.1 +FCLASS=1.0 or +FCLASS=1 - Select Facsimile Class 1 Mode
+FCLASS=1.0 or +FCLASS=1 selects the Fax Class 1.0 Mode (see Section 3.2.1.2).
The Fax Class 1.0 Mode commands and responses described in this section are
applicable when command +FCLASS=1.0 or 1. (See Section 3.2.1.2 for the definition of
the FCLASS command.)

4.2.1.2 +FAE - Auto Answer Enable

This command enables or disables fax adaptive answer.
Syntax
+FAE=<value>
Defined Values
<value> Decimal number corresponding to the selected option.
0 Disable data /fax auto answer mode. (Default.)
1 Enable data /fax auto answer mode. The modem determines the calling type and
issues DATA result code (13) if the caller is a data modem or issues FAX result code (15)
if the caller is a fax modem.

4.2.1.3 +FTS - Transmit Silence

This command causes the modem to terminate a transmission and wait for <time>
10-ms intervals before responding with the OK result code.
Syntax
+FTS=<time>
Defined Values
<time> Decimal number from 0 (default) to 255 which specifies the length of time in
10-ms intervals to
delay before responding with the OK result code after terminating the session.
Result Codes
OK Reported when transmission has been terminated for the specified amount of time.
ERROR <value> is invalid or this command is issued while the modem is on-hook.
Reporting Supported Range of Parameter Values
Command: +FTS=?
Response: +FTS: <time> range
Example: +FTS: 0-255

4.2.1.4 +FRS - Receive Silence

This command causes the modem to listen and report an OK result code when silence
has been detected on the line for the specified period of time. This command will
terminate when the required period of silence is detected or when the DTE sends the
modem another character other than XON or XOFF, which is discarded. In either event,
the OK result code is returned.
This command is aborted if any character is received from the DTE after receipt of the
command but before the time delay elapses. In this case, the modem discards the
aborting character and issues an OK result code.
Syntax
+FRS =<time>
Defined Values
<time> Decimal number from 0 (default) to 255 which specifies the length of time in
10-ms intervals to
delay before responding with the OK result code after detecting silence on the line.