Description
3.3 Installation
3.3.9.2

Zone 2, type of protection increased safety Ex "ec" or Non sparking "nA"

30
II
3
2
CE - or EAC marking
Code for prevention of explosions
Device group: II not for mines susceptible to firedamp, but other hazardous zones
Device category: 3 for infrequent, short-term danger
Atmosphere: G for gas
Explosion protection: International
Type of protection: "ec" increased safety or "nA" for Non Sparking
Explosion group: IIC for acetylene IIB für ethylene
Temperature Class: T3 for maximum surface temperature of 200° C
Device protection level: Gc for an extended level of protection in hazardous zones with
explosive gas mixtures
Identification number or name of nominated testing agency
Zone 2
"X" special conditions
G
Ex
ec
Ex
nA
IIC
1LA5/6/7/9, 1LG4/6, 1MA6/7, 1MB..1/2/3/4/5 - SH 63 ... 355
IIC
T3
T3
Gc
Operating Instructions, 06/2018, A5E44455710A
Gc
X