Avoidance Of Damage To Rolling Bearings During Stoppages; Decommissioning The Machine; Re-Commissioning The Machine - Siemens SIMOTICS XP 1MB1 series Operating Instructions Manual

Low-voltage motors
Hide thumbs Also See for SIMOTICS XP 1MB1 series:
Table of Contents

Advertisement

Operation
8.5 Stoppages
Explosion hazard
If the anti-condensation heating is switched on directly after the machine is switched off, the
temperature class or the maximum surface temperature of the machine can be exceeded.
In an explosive atmosphere, there is a risk of an explosion. This can result in death, serious
injury or material damage.
• Only switch on the anti-condensation heating after the motor has been switched off.
8.5.1

Avoidance of damage to rolling bearings during stoppages

Extended stoppages at the identical or almost identical resting position of the rotor in the
rolling bearings can result in damage, such as brinelling or corrosion.
● During stoppages, regularly start up the machine for a brief period once a month. As a
minimum, turn the rotor several times.
If you have uncoupled the machine from the driven machine and secured the rotor with a
rotor shipping brace, then remove this before turning the rotor over or starting up the
machine.
Make sure that the resting position of the rotor after the rotor has been turned over is
different from its previous position. Use the fitted key or the coupling halves as reference
markers.
● During recommissioning, refer to the information in Chapter "Commissioning".
8.5.2

Decommissioning the machine

● Record the decommissioning steps. This log will be useful upon recommissioning.
● If the machine is going to be out of service for longer than six months, then take the
necessary measures for preservation and storage. Otherwise, the machine could be
damaged as a result of not being operated.
8.5.3

Re-commissioning the machine

When you re-commission the machine, proceed as follows:
● Study the record made when the machine was decommissioned, and reverse the
measures that were taken for conservation and storage.
● Perform the measures listed in the "Commissioning" section.
See also
Commissioning (Page 87)
106
WARNING
Carefully comply with the data on the anti-condensation heating plate.
1LA5/6/7/9, 1LG4/6, 1MA6/7, 1MB..1/2/3/4/5 - SH 63 ... 355
Operating Instructions, 06/2018, A5E44455710A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents