Cooling And Ventilation; Machines With A Fan; Machines Without A Fan (Optional) - Siemens SIMOTICS XP 1MB1 series Operating Instructions Manual

Low-voltage motors
Hide thumbs Also See for SIMOTICS XP 1MB1 series:
Table of Contents

Advertisement

Description
3.3 Installation
Feature
Electrical equipment for use in the presence of com-
bustible dust - Part 17: Inspection and maintenance of
electrical systems in hazardous areas (except under-
ground excavation)
Electrical equipment for hazardous gas atmospheres,
Part 19: Repairs and overhauls
Potentially explosive atmosphere - Part 31: Device
dust explosion protection by enclosure "t"
Directive on the approximation of the laws of the Mem-
ber States concerning equipment and protective sys-
tems intended for use in hazardous areas.
3.3.2

Cooling and ventilation

The machines of this series are three-phase induction machines with a closed primary
(internal) cooling circuit and an open secondary cooling circuit (surface cooling). The surface
cooling varies depending on the version.
3.3.2.1

Machines with a fan

Self-ventilation (standard): Cooling method IC 411 according to EN / IEC 60034-6
Located at the ND end of the stator housing is an air intake cowl that guides the external air
on its way to the motor. The external air is drawn in through openings in the air intake cowl
and flows axially across the outer cooling ribs of the motor frame. The fan wheel for the
external flow of cooling air is attached to the machine shaft.
The fan wheels are bidirectional.
Check the cooling effect below rated speed in the case of frequent switching or braking – or
if the speed is controlled continually below the rated speed.
Forced ventilation (optional): Type of cooling IC 416 in accordance with EN / IEC 60034-6
Cooling that does not depend on the speed is achieved by means of a unit that is
independent of the motor operating state (forced ventilation). This unit is closed to the
outside by a fan cover. It has its own main drive with fan impeller which creates the cooling
air flow required for cooling the motor.
3.3.2.2

Machines without a fan (optional)

Cooling method IC 410
Surface cooling by free convection: Cooling method IC 410 according to EN / IEC 60034-6
Cooling method IC 418
Surface cooling by relative movement of cooling air: Cooling method IC 418 according to
EN / IEC 60034-6
24
Standard
EN / IEC 60079-17
EN / IEC 60079-19
EN / IEC 60079-31
Directive 2014/34/EU
1LA5/6/7/9, 1LG4/6, 1MA6/7, 1MB..1/2/3/4/5 - SH 63 ... 355
Operating Instructions, 06/2018, A5E44455710A
EAC
GOST 30852 16 -
2002
GOST 30852 18 -
2002
GOST R
IEC 60079-31
TR CU