Mounting The Output Elements - Siemens SIMOTICS XP 1MB1 series Operating Instructions Manual

Low-voltage motors
Hide thumbs Also See for SIMOTICS XP 1MB1 series:
Table of Contents

Advertisement

Assembly
5.4 Installing the machine
To avoid stressing the motor feet, the overall flatness of the installation surfaces must satisfy
the values in the following table:
Table 5- 3
If shims are necessary for height adjustment and to avoid stresses, make them out of
adequately sized pieces of flat rolled strip. Complete balancing of the rotor together with the
transmission element may be found necessary.
5.4.5

Mounting the output elements

Balance quality
The rotor is dynamically balanced. For shaft ends with feather keys, the balancing type is
specified using the following coding on the rating plate:
● "H" means balancing with a half feather key
● "F" means balancing with a whole feather key
● "N" means balancing without a featherkey.
Figure 5-1
64
Overall flatness of the installation surfaces
Shaft height
≤ 080
090 - 355
≥ 400
Balancing type on the drive-end side
Overall flatness of the installation surfaces
0.1 mm
0.2 mm
0.3 mm
1LA5/6/7/9, 1LG4/6, 1MA6/7, 1MB..1/2/3/4/5 - SH 63 ... 355
Operating Instructions, 06/2018, A5E44455710A