BEA SUPERSCAN-T Manual page 7

Door-mounted, presence sensor for automatic, pedestrian doors
Hide thumbs Also See for SUPERSCAN-T:
Table of Contents

Advertisement

4
MODULE POSITION & ANGLE ADJUSTMENTS (cont.)
ANGLE ADJUSTMENTS
Each module's angle may be set independently. Use the diagrams and chart
below to adjust the module to obtain the correct angle.
Angles may need to also be adjusted after power-up and walk-testing.
1. Use the orientation shown to the right to insert the module into the clip.
2. Use the chart below to determine the clip setting for the desired angle.
The red line indicates the part of the module that will be set into the clip.
INACTIVE ZONE (Y, below)
DISTANCE FROM FLOOR
8"
12"
16"
20"
24"
28"
5
DETECTION ZONE ADJUSTMENTS
Jumper 1 must be set to Normal Mode (see page 5) to make adjustments.
1. Power sensors with 12 – 24 VAC/VDC ±10%. LED should reflect Jumper 2 configuration (see page 5).
2. Use a white, gray, or black piece of cardboard (roughly 8" x 11") and hold it as shown in the diagram on the
previous page.
3. Lift cardboard from the floor until it is detected. This determines the height of the inactive area (labeled "Y"
in the diagram). If this height is not between 12" – 16" above the floor OR does not meet your requirements,
an adjustment must be made to the detection distance.
- if zone Y is too high, turn the adjustment knob clockwise to increase the detection distance and
decrease zone Y
- if zone Y is too low, turn the adjustment knob counterclockwise to decrease the detection distance and
increase zone Y
75.5911.03 SUPERSCAN-T 20180719
75.5911.03 SUPERSCAN-T 20180719
0
0
0
0
0
0
Measurements are based on a 79" mounting height.
SUPERSCAN-T
CARD-
BOARD
Each module's detection zone may be set independently upon power-on.
SUPERSCAN-T ANGLE
10°
6"
12 1/2"
19 1/4"
6"
12"
18"
5 1/2"
11 1/4"
16 3/4"
5 1/4"
10 1/2"
16"
5"
9 3/4"
14 3/4"
4 1/2"
9"
13 1/2"
SUPERSCAN-T
CARDBOARD
A
B
15°
20°
25°
26"
33 1/4"
24 1/2"
31 1/2"
23 1/4"
29 1/2"
21 1/2"
27 1/2"
20"
25 1/2"
18 1/2"
23 3/4"
IR
ANSI 156.10 compliance:
At 28" from the floor, the
X
inactive zone shall not
Y
exceed 5"
8 7 6 5 4 3 2 1
CLIP SETTINGS:
1
0° = B1
2
3
5° = B2
4
5
10° = A2
15° = A3
20° = A4
25° = A5
}
X, below
Page 7 of 8