Available combination of network

Ethernet port (P1 and P2) of the RJ71EN71 can be used in the following network depending on the engineering tool setting.
( GX Works3 Operating Manual)
• Ethernet
• CC-Link IE Controller Network
• CC-Link IE Field Network
• Q-compatible Ethernet
The following table lists the available combination of network and setting in GX Works3.
Network
combination
Ethernet only
CC-Link IE Controller
Network only
CC-Link IE Field
Network only
Ethernet + CC-Link IE
Controller Network
Ethernet + CC-Link IE
Field Network
Q-compatible Ethernet
*1 The name in parentheses is the abbreviation of the network type.
• When the RJ71EN71 is used in the redundant system of the CPU module or the system of the remote head
module, CC-Link IE Controller Network and CC-Link IE Field Network cannot be used.
• When the RJ71EN71 is mounted with the Process CPU or Safety CPU, CC-Link IE Controller Network
cannot be used.
1 PART NAMES
18
1.1 RJ71EN71
Setting in GX Works3
*1
Model
Port 1
network type
RJ71EN71 (E+E)
Ethernet
RJ71EN71
CC-Link IE
(CCIEC)
Control
RJ71EN71
CC-Link IE Field
(CCIEF)
RJ71EN71
Ethernet
(E+CCIEC)
RJ71EN71
Ethernet
(E+CCIEF)
RJ71EN71 (Q)
Q Compatible
Ethernet
Description
Port 2
network type
Ethernet
Different network between P1
and P2 can be connected to
Ethernet.
CC-Link IE
P1 and P2 can be connected to
Control
CC-Link IE Controller Network
CC-Link IE Field
P1 and P2 can be connected to
CC-Link IE Field Network
CC-Link IE
P1 can be connected to Ethernet
Control
and P2 can be connected to CC-
Link IE Controller Network.
CC-Link IE Field
P1 can be connected to Ethernet
and P2 can be connected to CC-
Link IE Field Network.
A setting for replacement from
the MELSEC-Q series Ethernet
interface module RJ71EN71 can
be connected to Ethernet without
changing I/O signal and buffer
memory from the MELSEC-Q
series Ethernet interface module.
Remarks
• P1 and P2 cannot be
connected to different CC-Link
IE Controller Network.
• P1 and P2 cannot be set
different station numbers.
• P1 and P2 cannot be
connected to different CC-Link
IE Field Network.
• P1 and P2 cannot be set
different station numbers.
CC-Link IE Controller Network
cannot be configured in ring
topology.
CC-Link IE Field Network cannot
be configured in ring topology.
• Some parameters cannot be
set.
• P2 cannot be used.