Protection Pass Mode; Cy920 Reboot Mode - Denon AVR-X1200W Service Manual

Integrated network av receiver
Hide thumbs Also See for AVR-X1200W:
Table of Contents

Advertisement

5. Protection Pass Mode

5.1. Actions
• This mode allows the power to be turned on without activating protections.
• This mode functions in the same way as normal power-on, except that protections are not activated.
5.2. Operations
AVR-X1200W
· While holding down buttons "TUNER PRESET CH +", "ZONE2 SOURCE" and "STATUS" simultaneously, press the
power button to turn on the power.
AVR-S710W
· While holding down buttons "ZONE2 SOURCE", "TUNER PRESET CH +" and "TUNE +" simultaneously, press the pow-
er button to turn on the power.
The device returns to the normal display message after the following is displayed.
FLD
P r o t e c t i o n
This is displayed for 5 seconds before returning to the normal display.

6. CY920 Reboot Mode

6.1. Actions
• The CY920 is restarted after CY920 hang up.
• The CY920 can be restarted even in the network standby setting.
("Setup menu" – "Network" – "IP Control" – "Always On")
6.2. Operations
(1) Turn the "MAIN ZONE" button on and set the input source to NETWORK.
(2) While the power is on, hold down buttons "TUNER PRESET CH +" and "TUNER PRESET CH -" for at least 3 sec-
onds.
(3) Display during CY920 reboot
FLD
N e t w o r k
(4) Returns to the normal display.
NOTE :
• After rebooting CY920, the same operation is not accepted for 1 minute.
• Reception is prohibited during update, save and load.
P a s s
R e s t a r t
49