KM 5773
Remedy:
1. Disconnect and reconnect power.
2. Check the power electronic (1A3/2A3/3A3 - side where FE is displayed) and
replace it as necessary; refer to Section 010-4.9.
3. Check the filter/control electronic (1N1/2N1) and replace it as necessary. See
Section 010-4.10.
3.15
Fault Code FE 35
Cause:
Low voltage.
Remedy:
Check the supply voltage (208 or 240 volts between L1 and L2).
Cause:
Connection fault.
Remedy:
Check the power supply connection.
Cause:
Ribbon cable between filter electronic and power electronic defective.
Remedy:
Check the ribbon cable (including plugs) between the filter electronic (N1-8) and
the power electronic (side where FE is displayed). Replace as necessary.
Cause:
Filter electronic fault.
Remedy:
1. Disconnect and reconnect power.
2. Check the filter electronic and replace as necessary; see Section 010-4.10.
3.16
Fault Code FE 36, FE 38, FE 40
Cause:
Selection electronic defective.
Remedy:
Check the selection electronic and replace as necessary; see Section 010-4.6.
Cause:
Wiring harness between selection electronic and filter/control electronic is open-
circuited.
Remedy:
1. Disconnect and reconnect power.
2. Check the wiring harness between the selection electronic and filter/control
electronic; replace as necessary.
3. Check the filter/control electronic and replace as necessary; see Section 010-
4.10.
3.17
Fault Code FE 39
Cause:
Incorrect model version programmed.
Remedy:
Program the correct model version; see Section 010-4.1.
33