Pitch Tower (Every 6 Months)
Perform the following lubrication procedure once every
6 months.
1. Locate the Zerk grease fitting just below the pitch
adjustment lever on either pitch tower (Figure 30).
Remove the Zerk grease fitting cap and set it aside.
ZERK
FITTING CAP
PITCH
ADJUSTMENT
LEVER
Figure 30. Pitch Tower Lubrication
2. Wipe the Zerk grease fitting clean to prevent abrasive
material from entering the fitting during lubrication.
3. Lubricate the Zerk grease fitting with one shot of
multipurpose grade grease. Replace the Zerk grease
fitting cap when finished.
4. Repeat steps 1–3 for the grease fitting on the remaining
pitch tower.
HHNG5 RIDE-ON TROWEL • OPERATION MANUAL — REV. #1 (07/05/18) — PAGE 37
ZERK GREASE
FITTING
CHECKING THE DRIVE BELT
The drive belt needs to be changed as soon as it begins
to show signs of wear. NEVER reuse a belt under any
circumstances. Indications of excessive belt wear are
fraying, squealing when in use, belts that emit smoke or a
burning rubber smell when in use.
To gain access to the drive belt (Figure 31), remove the
drive belt guard cover, then visually inspect the drive belt
for signs of damage or excessive wear. If the drive belt is
worn or damaged, replace the drive belt.
OIL SOAKED
GLAZED
CRACKS
SIDEWALL
WEAR
Figure 31. Drive Belt Inspection
WARNING
NEVER attempt to insert hands or tools
into the drive belt area while the engine
is running and the safety guard has been
removed. Keep fingers, hands, hair and
clothing away from all moving parts to
prevent bodily injury.
WARNING
DO NOT remove the drive belt guard
cover until the muffler has cooled. Allow
the entire trowel to cool down before
performing this procedure.
MAINTENANCE
CORD FAILURE
MISSING RUBBER