1-2 Major Component Specifications
(A) Indoor Unit
MODEL No.
Source
Remote controller (Option)
Controller P. C. B Ass'y
Control circuit fuse
Fan (Number ... diameter)
Fan motor
Model
Source
No. of pole ... r.p.m. (230 V, High)
Nominal output
Coil resistance
(Ambient temperature 68 °F)
Safety device
Operating temperature
Run capacitor
1
Heater Ass'y (Aux. Heater)
Model
Input (230 / 208 V)
Protective thermostat
Thermo fuse
2
Heat exchanger
Coil
Rows ... Fins per inch
Face area
Auto louver motor
Model No.
3
Auto louver motor ... Rated
Coil resistance (Ambient temperature 77 °F)
4
5
6
Wired or Wireless (See Unit Specification)
in.
(mm)
Centrifugal (4 ... 5-29/32(150))
rpm
W
BRW - WHT
WHT - VLT
VLT - ORG
°F
Open
°F
Close
µF
VAC,
KW
CS- 12AL OFF 122 ± 6°F, ON 104 ± 10°F
Aluminum plate fin / Copper tube
2
2
ft.
(m
)
V, W, rpm
DATA SUBJECT TO CHANGE WITHOUT NOTICE
I-34
1. Specifications
THH3672R
230 - 208 V / 1 phase / 60 Hz
CR - TH2672
250 V, 5 A
KFG4X - 101C6P
230 - 208 V / 1 phase / 60 Hz
4 ... 1,015
100
:
61.05
,
ORG - YEL
:
9.955 ,
YEL - BLK
:
9.576 ,
BLK - PNK
± 14.4
266
174.2 ± 27
440 V , 4 µF
AH - 2.4THS3632
2.4 / 1.94
SF96U Cut - off 205 ± 4°F
3 ... 14.9
3.51 (0.326)
MT8 - 3C
240 VAC , 3 W , 3 rpm
16,430 Ω ± 8 %
:
13.23
:
19.25
:
10.81
SM831148