Download Print this page

Sanyo XHW3672R Specifications

Ceiling recessed air conditioner
Hide thumbs Also See for XHW3672R:

Advertisement

Quick Links

Split System Submittal Data
System: 36XW72R
Ceiling Recessed Air Conditioner
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Power
V/PH/Hz
Circuit Ampacity
(A)
Fuse Size, Max.
(A)
Compressor
No. used
R.L. Amps - L.R.
Outdoor Unit
Fan type
Dia. (in.) - No. Speeds
Type Drive - No. Speeds
No. Poles
(RPM)
No. Motors
(High)
CFM
(A)
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
(sq.ft.)
Face Area
Tube Size
Indoor Unit
Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
No. Poles
No. Motors
(W)
(HI/Med/Lo)
CFM
Indoor Sound Rating
(Hi) (dB-A)
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
(sq.ft.)
Tube Size
(in.)
Drain Connection Size
Indoor/Outdoor: XHW3672R/C3672R
Grille: PNR-XH3642
General Data (at 230V)
230/208/1/60
15-35 Indoor-Outdoor
15-35 Indoor-Outdoor
DC Motor
(A)
16.4-17.5
Propeller
18-7/64-1
Direct Inverter
8 - 830
(W)
Aluminum Fin & Copper Pipe
Slit Plate - Inner Rif ed
2 - 14.1
(in.)
17-7/16-1
3 & Auto
(RPM, High)
1050/840/720
(A)
Aluminum Plate Fin & Copper Tube
Slit Plate - Inner Rif ed
2-14.9
(in.)
1-17/64
Approval:
Date:
Construction:
Unit #:
Drawing #:
Refrigerant
Lbs. - R410a (outdoor unit)
Control
1
Connection
Line Length, Max (ft.)
Lift Difference, Max (ft.)
Line Size
Line Size
Dimensions
Indoor Unit
1 - 90
1942
Outdoor Unit
17.3
Weight
Net
Shipping
7.26
3/8"
Shipping Volume
Performance Data @ ARI Standard Conditions (230/208V)
Turbo
Cooling
Total Capacity
6-467
Sensible Capacity
1 - 60
Latent Capacity
SEER
Dehumidification
44
0.9
Amps
Power Inputs
Outdoor Sound Rating
8.2
9/32"
Electric Expansion Valve
50 (outdoor lower), 100 (outdoor higher)
(in. O.D. Discharge)
(in. O.D. Suction)
(in.)
(Uncrated)
14-31/64 x 45-9/32 x 33-55/64
(Crated)
12-13/32 x 44-19/64 x 33-9/32
(Uncrated)
30-23/32 x 37 x 13-3/8
(Crated)
34-31/32 x 39-31/32 x 16-3/32
Indoor
(lbs.)
60
(lbs.)
71
Indoor
(cu.ft.)
10.6
(BTU/H)
32,600 (9,500-32,600)
(BTU/H)
(BTU/H)
(Pints/H)
(A)
(W)
(dB-A)
R410A
6.17
Flare
165
3/8"
5/8"
H x W x D
Outdoor
143
161
Outdoor
13.0
20,160
12,440
14.6
10.6
18.7/20.7
3,950/3,950
52

Advertisement

loading

Summary of Contents for Sanyo XHW3672R

  • Page 1 Split System Submittal Data System: 36XW72R Indoor/Outdoor: XHW3672R/C3672R Grille: PNR-XH3642 Ceiling Recessed Air Conditioner Job Name: Location: Engineer: Submitted to: Submitted by: Reference: General Data (at 230V) Power V/PH/Hz Circuit Ampacity Fuse Size, Max. Compressor No. used R.L. Amps - L.R.
  • Page 2 Night Setback Air Louver (Horizontal) (Vertical) Power Failure Automatic Restart Self-Diagnosis Air Filter Sanyo Commercial Solutions A Division of SANYO North America 1300 Michael Drive Wood Dale, IL 60191 USA www.sanyohvac.com Options Refrigerant Line Set Microprocessor Fresh Air Intake Airduct Extension...

This manual is also suitable for:

C3672rPnr-xh364236xw72r