Sanyo C4272R Service Manual page 36

Sanyo split system air conditioner service manual
Hide thumbs Also See for C4272R:
Table of Contents

Advertisement

1-2 Major Component Specifications
(A) Indoor Unit
MODEL No.
Source
Remote controller (Option)
Controller P. C. B Ass'y
Control circuit fuse
Fan (Number ... diameter)
Fan motor
Model
Source
No. of pole ... r.p.m. (230 V, High)
Nominal output
Coil resistance
(Ambient temperature 68 °F)
Safety device
Operating temperature
Run capacitor
1
Heat exchanger
Coil
Rows ... Fins per inch
Face area
Auto louver motor
2
Model No.
Auto louver motor ... Rated
Coil resistance (Ambient temperature 77 °F)
3
4
5
6
Wired or Wireless (See Unit Specification)
in.
(mm)
Centrifugal (4 ... 5-29/32(150))
rpm
W
BRW - WHT
WHT - VLT
VLT - ORG
°F
Open
°F
Close
µF
VAC,
Aluminum plate fin / Copper tube
ft.
2
(m
2
)
V, W, rpm
DATA SUBJECT TO CHANGE WITHOUT NOTICE
I-32
1. Specifications
TH4272R
230 - 208 V / 1 phase / 60 Hz
CR - TH2672
250 V, 5 A
KFG4X - 101C6P
230 - 208 V / 1 phase / 60 Hz
4 ... 1,099
100
:
61.05
,
ORG - YEL
:
9.955 ,
YEL - BLK
:
9.576 ,
BLK - PNK
± 14.4
266
174.2 ± 27
440 V , 5 µF
3 ... 14.9
3.51 (0.326)
MT8 - 3C
240 VAC , 3 W , 3 rpm
16,430 Ω ± 8 %
:
13.23
:
19.25
:
10.81
SM831148

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents