Sanyo C4272R Service Manual page 155

Sanyo split system air conditioner service manual
Hide thumbs Also See for C4272R:
Table of Contents

Advertisement

(2) [Alarm "P26"]
HIC PCB trouble)
Is power OK?
circuit wiring,
connector
connections, and
connections
Has filter PCB
RY001 or RY002
relay activated?
Disconnect
U.V.W. output
terminal on HIC PCB and
start operation.
Does alarm
compressor OK?
(Check for layer
short circuit.)
resistance
between
each terminal on
HIC PCB OK?
(See following
Replace outdoor unit
control PCB.
IGBT short-circuit protection on inverter control (IPDU) PCB
No
Yes
Are
No
reactor
OK?
Yes
No
Yes
Has filter PCB
AC fuse blown?
No
"P26"
occur?
Yes
Is
No
Yes
Is
Check HIC PCB.
No
Replace if PCB
has failed.
page.)
Yes
IV-9
4. Service procedures
Correct power line.
Correct.
Yes
Replace filter PCB.
No
Replace HIC PCB.
Replace compressor.
1
2
3
4
5
6
SM831148

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents