Download Print this page

Sanyo KHS3672R Datasheet

Wall mounted air conditioner
Hide thumbs Also See for KHS3672R:

Advertisement

Quick Links

Split System Submittal Data
System: 36KS72R Indoor/Outdoor: KHS3672R/C3672R
Wall Mounted Air Conditioner
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Power
V/PH/Hz
Circuit Ampacity
(A)
Fuse Size, Max.
(A)
Compressor
No. used
R.L. Amps - L.R.
Outdoor Unit
Fan type
Dia. (in.) - No. Speeds
Type Drive - No. Speeds
No. Poles
(RPM)
No. Motors
(High)
CFM
(A)
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
(sq.ft.)
Face Area
Tube Size
Indoor Unit
Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
(RPM, High)
No. Poles
No. Motors
(W)
(HI/Med/Lo)
CFM
Indoor Sound Rating
(Hi) (dB-A)
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
(sq.ft.)
Tube Size
Drain Connection Size
General Data (at 230V)
230/208/1/60
15-35 Indoor-Outdoor
15-35 Indoor-Outdoor
DC Rotary Inverter
(A)
16.4-17.5
Propeller
18-7/64-1
DC Motor
8 - 830
(W)
Aluminum Fin & Copper Pipe
Slit Plate - Inner Rifeled
2 - 14.1
(in.)
Cross Flow
4-13/18 L46 - 1
3 & Auto
4 - 1273
830/710/590
(A)
Aluminum Plate Fin & Copper Tube
Slit Plate - Inner Riffeled
3 - 12.7
(in.)
(in.)
1-1/4"
Approval:
Date:
Construction:
Unit #:
Drawing #:
Refrigerant
Lbs. - R410a (outdoor unit)
Control
1
Connection
Line Length, Max (ft.)
Lift Difference, Max (ft.)
Line Size
Line Size
Dimensions
Indoor Unit
1 - 90
1942
Outdoor Unit
17.3
Weight
Net
Shipping
7.26
3/8"
Shipping Volume
Performance Data @ ARI Standard Conditions (230/208V)
Cooling
Total Capacity
Sensible Capacity
1 - 50
Latent Capacity
SEER
Dehumidification
48
0.5
Amps
Power Inputs
Outdoor Sound Rating
3.23
3/8"
Electric Expansion Valve
50 (outdoor lower), 100 (outdoor higher)
(in. O.D. Discharge)
(in. O.D. Suction)
(in.)
(Uncrated)
14-9/16 x 59-1/16 x 9-7/16
(Crated)
18-7/16 x 62-9/16 x 12-9/16
(Uncrated)
30-23/32 x 37 x 13-3/8
(Crated)
34-31/32 x 39-31/32 x 16-3/32
Indoor
(lbs.)
72.8
(lbs.)
90.4
Indoor
(cu.ft.)
8.4
(BTU/H)
31,400 (9,500-31,400)
(BTU/H)
(BTU/H)
(Pints/H)
(A)
(W)
(dB-A)
R410A
6.17
Flare
165
3/8"
5/8"
H x W x D
Outdoor
143
161
Outdoor
13.0
22,030
9,370
15.9
10.0
17.9/19.8
3,750/3,750
52

Advertisement

loading

Summary of Contents for Sanyo KHS3672R

  • Page 1 Split System Submittal Data System: 36KS72R Indoor/Outdoor: KHS3672R/C3672R Wall Mounted Air Conditioner Job Name: Location: Engineer: Submitted to: Submitted by: Reference: General Data (at 230V) Power V/PH/Hz Circuit Ampacity Fuse Size, Max. Compressor No. used R.L. Amps - L.R. Outdoor Unit Fan type Dia.
  • Page 2 Power Failure Automatic Restart Indoor unit : KH3672R Self-Diagnosis Air Filter Dimensional Data for 36K72R Indoor unit : KH3672R Sanyo Commercial Solutions A Division of SANYO North America 1300 Michael Drive Wood Dale, IL 60191 USA www.sanyohvac.com Options Refrigerant Line Set Microprocessor...

This manual is also suitable for:

C3672r36ks72r