At the end of a pre-trip test, the message "P," "rSLts" (pretest results) will be displayed. Pressing the ENTER key
will allow the user to see the results for all subtests. The results will be displayed as "PASS" or "FAIL" for all the
tests run to completion.
A detailed description of the pre-trip tests and test codes is provided in
are provided in
Section
5.7.
4.7

DATACORDER

4.7.1

Description

The Carrier Transicold "DataCORDER" software is integrated into the controller and serves to eliminate the tem-
perature recorder and paper chart. The DataCORDER functions may be accessed by keypad selections and
viewed on the display module. The unit is also fitted with interrogation connections (see
used with the Carrier Transicold Data Reader to download data. A personal computer with Carrier Transicold
DataLINE software may also be used to download data and configure settings. The DataCORDER consists of:
Configuration Software
Operational Software
Data Storage Memory
Real Time Clock (with internal battery backup)
Six Thermistor Inputs
Interrogation Connections
Power Supply (battery pack)
The DataCORDER performs the following functions:
a. Logs data at 15, 30, 60, or 120 minute intervals and stores two years of data (based on one-hour
interval).
b. Records and displays alarms on the display module.
c. Records results of pre-trip testing.
d. Records DataCORDER and temperature control software generated data and events as follows:
Container ID Change
Software Upgrades
Alarm Activity
Battery Low (battery pack)
Data Retrieval
Defrost Start and End
Dehumidification Start and End
Power Loss (with and without battery pack)
Power Up (with and without battery pack)
Remote Probe Temperatures in the Con-
tainer (USDA Cold treatment and Cargo
probe recording)
Return Air Temperature
Set Point Change
Supply Air Temperature
Table
4–7. Detailed operating instructions
Real Time Clock Battery (internal battery)
Replacement
Real Time Clock Modification
Trip Start
ISO Trip Header (When entered via Interro-
gation program)
Economy Mode Start and End
"Auto 1/Auto 2/Auto 3" Pre-trip Start and End
Bulb Mode Start
Bulb Mode Changes
Bulb Mode End
USDA Trip Comment
Humidification Start and End
USDA Probe Calibration
Fresh Air Vent Position
- - - - -
4–15
Figure
4.1) which may be
T-359