6.14.2 Setting the operating pressure

Correct setting
The operating pressure for the pneumatic unit is 6 bar.
ATTENTION
Machine damage possible due to incorrect pressure.
Incorrect pressure can cause damage to the machine.
Make sure that the operating pressure is set correctly
before putting the machine into operation.
Fig. 48: Setting the operating pressure
2
0
1. Pull the turning handle (1) up.
2. Set the operating pressure in such a way that the pressure
indicator (2) indicates 6 bar precisely:
• To increase the pressure:
Turn the rotary handle (1) clockwise.
• To reduce the pressure:
Turn the rotary handle (1) counterclockwise.
3. Push the turning handle (1) down.

6.15 Oil lubrication