Siemens SINUMERIK 840D sl Operating Manual page 23

Sinumerik integrate create myconfig - eplan electric p8 add-in
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

● The device is considered from the viewpoint of EPLAN Add-In.
You will find further information on this in Section Requirement (Page 32).
● Always display the device as PLC unit.
● The connections with the corresponding bus data are exclusively of the "PLC connection
point and bus port" type.
● Only bus data of the "Profibus" and "Profinet" type is taken into account.
● The value of the EPLAN property "MasterSystemID" must be an integer.
● The EPLAN property "Position / Node ID" must be an integer. Use the "Position" instead
of the IP address for Profinet.
Note
Bus data - Internal/external PROFIBUS connection
Note that the bus data for the internal PROFIBUS connection of the NXs on the NCU is not
configured because it has already been permanently defined.
Configure the external PROFINET connection and the PROFINET interface.
SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In
Operating Manual, 12/2017, A5E43099659B-AA
Configuring with EPLAN Add-In
5.3 Define bus data