Download Print this page

BEA Fly Manual page 3

Request - to - exit sensor

Advertisement

PREPARING THE SENSOR (cont.)
4
Reinstall the mask (if needed)
by placing the mask inside
the cover so that the legs of
the mask slide into the clips.
Gently work the mask's legs
until it clicks.
NOTES:
1. Sensitivity, relay output, and hold time can all be adjusted.
2. It is easiest to insert both legs of the cover at once and then push the two pieces together.
MOUNTING & WIRING
1. Attach template to frame above door.
2. Drill holes and pass cable through template.
3. Place sensor on template and attach using
the provided screws.
The sensor must be secured to avoid vibrations.
Ensure no objects are present in the sensing field during
set-up.
NOTES:
1. If using the Ceiling Adapter or Surface Adapter, ensure that proper mounting templates are used.
75.0152.04 FLY 20180523
75.0152.04 FLY 20180523
Adjust
application.
for DIP switch settings.
DIP SWITCH
SETTING
1
Sensitivity
2
Relay Output
Hold Time (FLY)
3
Hold Time (FLY ERT)
* Factory Settings are in bold.
** Passive output: relay contact open during detection, closed during non-detection
*** Active output: relay contact closed during detection, open during non-detection
5
ON
OFF
1
2
3
DIP
switches
See table below
1
ON: high
OFF: low
ON: passive output **
OFF: active output ***
ON: 2 sec
OFF: 0.5 sec
ON: 30 sec
OFF: 15 sec
4. Connect the sensor cable to the unit.
1
5. The LED will flash for a few seconds after
6
for
Replace
matching
(center of cover) to the slot
in the housing, then gently
push the cover until it snaps.
ADJUSTMENTS*
Use the table provided here to ensure
correct wiring.
Input power is not
polarity-sensitive.
start-up. LED will also illuminate when
the sensor detects motion.
PIN
FUNCTION
1
12 − 24 V (POWER)
2
12 − 24 V (POWER)
3
RELAY COM
4
RELAY NO
5
RELAY NC
the
cover
by
the
small
tab
2
Page 3 of 4
Page 3 of 4

Advertisement

loading

This manual is also suitable for:

Fly ert