MC_Stop (Forced Stop)

Name
MC_Stop_JEC
Overview
Item
Description
Function overview
Forcibly stops the specified axis.
Symbol
[Structured Ladder]
Symbol
MC_Stop_JEC (Axis, Execute, Done, Busy, Error, ErrorID)
[Structured Text]
Labels
■I/O label
No.
Variable name
Name
(1)
Axis
Axis information
■Input labels (Load: П: Always, : Only at start)
No.
Variable name
Name
(2)
Execute
Execution command
■Output labels
No.
Variable name
Name
(3)
Done
Execution
completion
(4)
Busy
Executing
(5)
Error
Error
(6)
ErrorID
Error code
(1)
DUT: Axis
(2)
B: Execute
Data type
AXIS_REF_JEC
Data type
Bit
Data type
Bit
Bit
Bit
Word [unsigned]
MC_Stop_JEC
Axis :DUT
Done :B
Busy :B
Error :B
ErrorID :UW
Setting range
Description
Page 59 AXIS_REF_JEC (Axis information)
Import
Setting
Description
range
ON, OFF
ON: The FB is executed.
Default value
Description
OFF
It indicates that the velocity has reached 0.
OFF
It indicates that the velocity is decreasing to 0.
OFF
When ON, it indicates that an error has occurred in
the FB.
0
The error code generated in the FB is returned.
(1)
(3)
(4)
(5)
(6)