11 Troubleshooting

11.1

Error codes

Fault
Error description
code
0
No fault
10
Outside temp sensor fault
20
Boiler temperature 1 sensor fault
25
Boiler temperature solid fuel sensor fault
26
Boiler temperature solid fuel sensor fault
28
Boiler temperature solid fuel sensor fault
30
Flow temperature 1 sensor fault
32
Flow temperature 2 sensor fault
38
Boiler temperature solid fuel sensor fault
40
Return temperature 1 sensor fault
46
Boiler temperature solid fuel sensor fault
47
Common return temp sensor fault
50
DHW temperature 1 sensor fault
52
DHW temperature 2 sensor fault
54
Flow temperature DHW sensor fault
57
Drinking water circulation temperature sensor fault
60
Room temperature 1 sensor fault
65
Room temperature 2 sensor fault
68
Room temperature 3 sensor fault
70
Storage tank temp 1 (top) sensor fault
71
Storage tank temp 2 (bottom) sensor fault
72
Storage tank temp 3 (middle) sensor fault
73
Collector temperature 1 sensor fault
81
LPB short-circuit or no bus power supply
82
LPB address collision
83
BSB wire short-circuit
84
BSB address collision
85
BSB wireless commissioning fault
91
EEPROM fault: information of locking mechanism
98
Expansion module 1 fault (collective fault)
99
Expansion module 2 fault (collective fault)
100
Two time masters (LPB)
102
Clock time master without backup
105
Maintenance message
109
Boiler temperature monitoring
110
Safety temperature limiter lockout
111
Temperature monitor switching off
7703046 - 01 - 23072018
11.1.1

Fault code table

The following is an extract from the fault code table. If other fault codes
are displayed, please inform the installer.
Explanations/causes
Check connection or outside temp sensor, emergency opera­
tion
Check connection, inform heating specialist
Check connection, inform heating specialist
Check connection, inform heating specialist
Check connection, inform heating specialist, emergency oper­
1)
ation
Check connection, inform heating specialist
Check addresses of connected control modules
Check connection of the room units
2 room devices have the same assignment (prog.no. 42)
Internal fault LMS, process sensor, replace LMS, heating spe­
cialist
Check time master
See maintenance code (press information button once) for de­
tailed information
No heat removal, faulty sensor, STB/interruption, possible
short circuit in the gas valve
vice to cool down and carry out reset; if the fault occurs sever­
al times inform the installer
No heat supply; pump defect, radiator valves closed