9 Settings
126
Paramount five 30 – 115
Burner start interval (7042)
Setting of the interval for burner starts for maintenance.
Burn starts since maint (7043)
Burner starts since the last maintenance.
Important
The burner starts are only counted, when the maintenance
message has been activated.
Maintenance interval (7044)
Setting of maintenance interval in months.
Time since maintenance (7045)
Passed time since the last maintenance interval.
Important
The time is only counted, when the maintenance message has
been activated.
Fan speed ionization current (7050)
Speed limit from which the ionisation current service alarm should be set
(prog. no. 7051), if the ionisation current monitoring and therefore a speed
increase based on too low ionisation current active is.
Message ionization current (7051)
Function for display and reset of the burner ionization current maintenance
message. The maintenance message can only be reset if the reason for
maintenance has been eliminated.
Chimney sweep function (7130)
The chimney sweep function is switched on or off under this prog no.
Important
The function is switched off by the settingOff or automatically if the
maximum boiler temperature is reached.
It can also be directly activated via the chimney sweep button.
Manual control (7140)
Activation of manual control. If the manual control function is activated the
boiler is controlled to the setpoint manual control. All the pumps are
switched on. Additional request will be ignored!
Controller stop function (7143)
If the controller stop function is activated, the burner output set in the
setpoint controller stop is directly requested by the device.
Controller stop setpoint (7145)
With activated controller stop function the output set here is requested by
the device.
Compulsory heat draw-off DHW (7165)
This parameter is used to set that heat pumping to the domestic hot water
circuit takes priority when the chimney sweep function is active.
Off: Compulsory pumping of the heat to the heating circuits.
On: When the chimney sweep function is active, heat is pumped with
priority into the domestic hot water circuit.
Telephone customer service (7170)
Here the desired telephone number of customer service can be entered.
PStick storage pos (7250)
Via the parameter PStick storage pos the data set (data set number on the
stick) can be selected which should be written or read.
7703046 - 01 - 23072018