DHW charging priority (1874, 1924, 1974)
Setting as to whether domestic hot water charging takes priority over the
consumer circuit/swimming pool circuit or not.
Excess heat draw (1875, 1925, 1975)
If an excess temperature discharge is activated, the excess energy can be
discharged heat being drawn by the consumer circuits. This can be set
separately for each consumer circuit.
With buffer (1878, 1928, 1978)
This parameter establishes whether the heating circuit can be supplied by
a buffer or storage tank or only by a heat generator. The function also
determines whether the system pump goes into operation when a heat
demand is submitted.
No: The heating circuit is supplied from the boiler.
Yes: The heating circuit can be supplied from the buffer storage tank.
With prim contr/system pump (1880, 1930, 1980)
No: The consumer circuit is supplied without primary control unit/system
pump
Yes: The consumer circuit is supplied from the primary controller on/by
the system pump.
9.2.9

Swimming pool

Swimming pool
The controller enables a swimming pool to be heated with solar energy or
via heat generators, each with a separately adjustable setpoint. For solar
heating, the priority of the swimming pool heating relative to the storage
tank charging can be set.
Setpoint solar heating (2055)
When solar energy is used, the swimming pool is heated to the setpoint
set here.
Setpoint source heating (2056)
When using the generator heating, the swimming pool is heated to the
setpoint set here.
Charging priority solar (2065)
Setting of which priority the swimming pool will be solar heated. The
priority for the DHW and charging buffer is set under Prog. no. 3822.
Priority 1: Charging the swimming pool has top priority.
Priority 2: Charging the swimming pool has middle priority (between the
domestic water and the buffer storage tank).
Priority 3: Charging the swimming pool has lowest priority (after the
domestic water and the buffer storage tank).
Important
Release and priority can also be affected by the Hx inputs (see
also program no. 3822).
For more information, see
Charging prio storage tank (3822), page 105
Swimming pool temp max (2070)
If the swimming pool temp reaches the heating limit set here, the collector
pump is switched off. It is again released if the swimming pool temp has
dropped by 1°C below the maximum heating limit temperature.
With solar integration (2080)
Setting, of whether the swimming pool heating can be done by solar
energy or not.