Model Number Descriptions; Unitrane™ Fan Coil/Force Flo™ Cabinet Heater - Trane UniTrane Fan Coil Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

Model Number Descriptions

UniTrane™ Fan Coil/
Force Flo™ Cabinet
Heater
Following is a complete description of
the UniTrane fan coil and Force Flo
cabinet heater model number. Each digit
in the model number has a
corresponding code that identifies
specific unit options.
Note: Not all options are available on all
cabinet styles. Contact your local
Trane sales representative for
more information.
Digits 1, 2 — Unit Type
FC =
UniTrane fan coil
FF =
Force Flo cabinet heater
Digit 3 — Cabinet Type
A
=
Vertical concealed
B
=
Vertical cabinet
C
=
Horizontal concealed
D
=
Horizontal cabinet
E
=
Horizontal recessed
F
=
Wall-hung cabinet (FF only)
H
=
Vertical recessed
J
=
Vertical slope-top cabinet
M =
Inverted vertical cabinet
(FF only)
N
=
Inverted vertical recessed
(FF only)
P
=
Compact concealed
Digit 4 — Development
Sequence "B"
Digits 5, 6, 7 — Unit Size
020
040
080
030
060
100
120
Digit 8 — Unit Voltage
1
=
115/60/1
2
=
208/60/1
3
=
277/60/1
4
=
230/60/1
5
=
208/60/3 (FF only)
6
=
230/60/3 (FF only)
7
=
480/60/3 (FF only)
8
=
110-120/50/1 (FF only)
9
=
220/50/1
A
=
220-240/50/3 (FF only)
B
=
380-415/50/3 (FF only)
UNT-SVX07E-EN
Digit 9 — Piping System/
Placement
A
=
No piping, RH, no auxiliary
drain pan
B
=
No piping, LH, no auxiliary
drain pan
C
=
No piping, RH, with auxiliary
drain pan
D
=
No piping, LH, with auxiliary
drain pan
E
=
No piping, RH, no auxiliary
drain pan, Extended End Pocket
F
=
No piping, LH, No Auxiliary
Drain Pan, extended end pocket
G
=
No piping, RH, with auxiliary
drain pan, extended end pocket
H
=
No piping, LH, with auxiliary
drain pan, extended end pocket
J
=
With piping package, RH
K
=
With piping package, LH
L
=
With piping package, RH,
extended end pocket
M =
With piping package, LH,
extended end pocket
Digits 10, 11 — Design
Sequence
Digit 12 — Inlets
A
=
Front toe space
B
=
Front bar grille
C
=
Front stamped louver
D
=
Bottom stamped louver
E
=
Bottom toe space
F
=
Back duct collar
G
=
Back open return
H
=
Back stamped louver
J
=
Top duct collar (FF only)
K
=
Exposed fan (Model P only)
L
=
Bottom filter (Model P only)
Digit 13 — Fresh Air Damper
0
=
None
A
=
Manual, bottom opening
B
=
Manual, back opening
C
=
Manual, top opening
D
=
Auto, 2-position, bottom
opening
E
=
Auto, 2-position, back opening
F
=
Auto, 2-position, top opening
G
=
Auto, economizer, bottom
opening
H
=
Auto, economizer, back opening
J
=
Auto, economizer, top opening
K
=
No damper, bottom opening
L
=
No damper, back opening
M =
No damper, top opening
Digit 14 — Outlets
A
=
Front duct collar
B
=
Front bar grille
C
=
Front stamped louver
D
=
Front quad grille
E
=
Bottom duct collar (FF only)
F
=
Bottom stamped louver
(FF only)
G
=
Top quad grille
H
=
Top bar grille
J
=
Top duct collar
Digit 15 — Color
0
=
No paint (concealed units only)
1
=
Deluxe Beige
2
=
Soft Dove
3
=
Cameo White
4
=
Driftwood Grey
5
=
Stone Grey
6
=
Rose Mauve
Digit 16 — Tamperproof Locks/
Leveling Feet
0
=
None
B
=
Keylock access door
C
=
Keylock panel and access door
D
=
Leveling feet
F
=
Keylock access door with
leveling feet
G
=
Keylock panel and access door
with leveling feet
Digit 17 — Motor
A
=
Free discharge ECM
B
=
High static ECM
Digit 18 — Coil
A
=
2-row cooling/heating
B
=
3-row cooling/heating
C
=
4-row cooling/heating
D
=
2-row cooling/1-row heating
E
=
2-row cooling/2-row heating
F
=
3-row cooling/1-row heating
G
=
2-row cooling only
H
=
3-row cooling only
J
=
4-row cooling only
K
=
2-row cooling/heating
electric heat
L
=
3-row cooling/heating
electric heat
M =
4-row cooling/heating
electric heat
N
=
Electric heat, single-stage
(FF only)
P
=
2-row cooling/heating
1-row heating
Q
=
2-row cooling/heating
2-row heating
R
=
3-row cooling/heating
1-row heating
U
=
Electric heat, two-stage
(FF only)
V
=
Electric heat, low kW, one-stage
(FF only)
W =
Steam distributing (FF only)
X
=
2-row cooling only, electric
heat
Y
=
3-row cooling only, electric
heat
Z
=
4-row cooling only, electric
heat
1 Designates coils provided with a
Note:
changeover sensor.
Digit 19 — Drain Pan Material
(Fan Coil) or Coil Series (Force
Flo)
1
=
108 FPF (steam only)
2
=
144 FPF (hot water only)
3
=
Polymer drain pan
4
=
Stainless steel main drain pan
1
1
1
1
with
1
with
1
with
1
with
1
with
1
with
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Force flo cabinet heater

Table of Contents