5-4

Diagram of Terminal Description

This section describes the wiring of the K6CM devices. Connect to the push-in Plus terminal blocks as
follows.
K6CM- VB M A -EIP
(1)
(2)
(2) Power voltage
A: 100 to 240 V AC
D: 24 V AC/DC
2
1
(No polarity)
External trigger input
3
4
5 V
680 Ω
+
Comparator
Do not use
Each transistor output terminal has the following functions.
Terminal
number
13,14
15,16
17,18
K6CM Motor Condition Monitoring Device User's Manual (N219)
2
1
1
3
0 V
Transistor output
1
Warning output of comprehensive alarm
2
Critical output of comprehensive alarm
3
Self-diagnosis error output
(1) Sensor input
VB: Vibration and
temperature sensor input
Red/
white
2
7
8
4
9
10
Black
CI: CT input
White
Output function
13 14
Transistor output
15 16
17 18
13 14
Interior
Function
5 Installation and Wiring
IS: ZCT (IRT) input
K6CM-VBS
K6CM-ISZ
(pre-amplifier)
(ZCT(IRT))
Red/
Red
Red
white
7
8
7
8
9 10
9 10
Black
Black
/white
K6CM-CIC
(CT)
Black
7
8
15 16
17 18
Interior
Interior
Black
/white
5
5 - 19