REDUCING HEAT LOSSES
The cold water line to and the hot water line from the water heater must be insulated in accordance with the
requirements of AS/NZS 3500.4. The insulation must be weatherproof and UV resistant if exposed.
The pipe work between the solar storage tank and the solar collectors may be required to be insulated. Refer
"Warning: Plumber Be Aware"
to
ANODE
The vitreous enamel lined cylinder of the water heater is only covered by the Rheem warranty when the total
dissolved solids (TDS) content in the water is less than 2500 mg/L and when the correct colour coded anode
is used. If an incorrect colour coded anode is used in the water heater, any resultant faults will not be covered
by the Rheem warranty. In addition, the use of an incorrect colour coded anode may shorten the life of the
water heater cylinder.
The correct colour coded anode for the water supply being used must be selected and fitted to the water heater
for the Rheem warranty to apply to the water heater cylinder (refer to
Anode Selection chart
on page 12). The black anode is typically fitted as standard.
If the TDS is greater than 600 mg/L and the anode has not been changed to a blue anode, there is the
possibility the anode may become overactive and hydrogen gas could accumulate in the top of the water heater
during long periods of no use. In areas where this is likely to occur, the installer should instruct the householder
on how to dissipate the gas safely (refer to
SADDLING - PIPE WORK
To prevent damage to the cylinder when attaching pipe clips or saddles to the water heater jacket, we
recommend the use of self-drilling screws with a maximum length of 13 mm. Should pre-drilling be required,
extreme caution must be observed when penetrating the jacket of the water heater.
Note: If the cylinder is damaged as a result of attaching pipe clips or saddles to the jacket, any resultant
faults will not be covered by the Rheem warranty.
BOOSTER HEATING UNIT
The booster heating unit is for heating the water at times of low solar energy gain, such as during very cloudy
or rainy weather, or during the colder months. Refer to
connection requirements and control options of the booster heating unit.
If this water heater is installed with an in-series booster, then the electric booster heating unit in the solar
storage tank will not need to be connected to a power supply.
on page 29.
Total Dissolved Solids
0 – 400 mg/L
400 – 600 mg/L
600 – 2500 mg/L
2500 mg/L +
"Caution"
INSTALLATION – SOLAR STORAGE TANK
"Water Supplies"
Anode colour code
Black
Black or Blue
Blue
Blue (no cylinder warranty)
on page 13).
"Connections – Electrical"
23
on page 12 and the
on page 45 for electrical