VANTAGE
®
500
WELDER / GENERATOR
MAINTENANCE
STORAGE: Store in clean, dry protected areas.
CLEANING: Blow out the generator and controls peri-
odically with low pressure air. Do this at least once a
week in particularly dirty areas.
BRUSH REMOVAL AND REPLACEMENT: It's nor-
mal for the brushes and slip rings to wear and darken
slightly. Inspect the brushes when a generator over-
haul is necessary.
CAUTION
• Do not attempt to polish slip rings while the
engine is running.
WARNING
• Service and Repair should only be performed by
Lincoln Electric Factory Trained Personnel.
Unauthorized repairs performed on this equip-
ment may result in danger to the technician and
machine operator and will invalidate your factory
warranty. For your safety and to avoid Electrical
Shock, please observe all safety notes and pre-
cautions.
------------------------------------------------------------------------

GFCI TESTING AND RESETTING PROCEDURE

The GFCI should be properly tested at least once every
month or whenever it is tripped. To properly test and
reset the GFCI:
• If the GFCI has tripped, first carefully remove any
load and check it for damage.
• If the equipment has been shut down, it must be
restarted.
• The equipment needs to be operating at high idle
speed and any necessary adjustments made on the
control panel so that the equipment is providing at
least 80 volts to the receptacle input terminals.
• The circuit breaker for this receptacle must not be
tripped. Reset if necessary.
• Push the "Reset" button located on the GFCI. This
will assure normal GFCI operation.
• Plug in night-light (with an "ON/OFF" switch) or other
product (such as a lamp) into the duplex receptacle
and turn the product "ON".
• Push the "Test" button located on the GFCI. The
night-light or other product should go "OFF".
• Push the "Reset" button, again. The light or other
product should go "ON" again.
If the light or other product remains "ON" when the
"Test" button is pushed, the GFCI is not working prop-
erly or has been incorrectly installed (miswired). If your
GFCI is not working properly, contact a qualified, certi-
fied electrician who can assess the situation, rewire the
GFCI if necessary or replace the device.
D-6
MAINTENANCE