2-3-5.
Elbow Sub Assembly/VF Mirror Assembly
Preparation
1.
Remove the VF assembly. (Refer to
2.
Remove the loupe assembly. (Refer to
3.
Remove the elbow assembly. (Refer to
Procedure
1.
Remove the two screws (P2.6 x 4) to detach the switching hinge block.
2.
Remove the two screws (B2 x 5) to detach the VF mirror assembly from the elbow sub assembly.
VF mirror assembly
B2 x 5
Note
Do not touch the mirror surface. If it is contaminated, clean it with a wiping cloth.
3.
Install the removed parts by reversing the steps of removal.