FAULT DIAGNOSTICS

7.1

Controller / module

Customer complaint
Cause
Running time too long
Alternating rinse technology, energy saving
Component is not actuated
Triac on the module
may be visible on the module
Regulator controller / power supply
in the module
Scorched connections
Mains plug
815_58300000003806_ara_en_e.doc – 30.01.12
does not switch properly, smoke traces
unit charred by humidity
Remedial action
Advise customer,
See Consumption rates
rinsing technology
Before replacing the module, always measure
the connected consumers (valves, actuators, etc.).
Comply with safety instructions
With the module also the sealing strip 298550 have to
be renewed.
The plug repair set 491817 can be used for defective
connections on electronic controllers.