Spray System - Siemens SE25M575GB series Repair Instructions

Table of Contents

Advertisement

4.16

Spray system

A
Roof shower head
B
Coupling
C
Supply pipe
815_58300000003806_ara_en_e.doc – 30.01.12
D
Pump sump
E
Lower spray arm
F
Upper spray arm
The rotor spray system consists of three spray levels, the lower spray
arm (E), the upper spray arm (F) and the roof shower head (A). Water
is supplied to the upper spray arm (F) and the roof shower head (A)
via the supply pipe (C) attached to the inside of the tank rear panel.
This pipe is connected by a direct plug-and-socket connection to one
of the two outlets on the instantaneous water heater situated under
the pump sump (D).
The upper spray arm (F) is attached by its inlet pipe directly to the top
basket. Connection to the supply pipe is by a variable coupling (B).
If appliances feature a height-adjustable top basket, the water inlet to
the spray arm is adjusted via this variable coupling.
The lower spray arm (E) is connected with its bearing assembly to the
second outlet of the instantaneous water heater directly via the pump
sump and features a nozzle on the underside for cleaning the surface
filter.