Circulation Pump (Sicasym) - Siemens SE25M575GB series Repair Instructions

Table of Contents

Advertisement

4.19

Circulation pump (SICASYM)

The circulation pump is driven by a single-phase a.c. motor.
The switching of the two motor windings with the motor capacitor is
actuated either via electronics or a relay on the motor connection
via the module
. In the start phase the two windings (one in series
with the capacitor) are connected in parallel to each other and directly
to the mains voltage and generate a very high starting torque. After
the switchover phase, the windings are then in series (one behind the
other), i.e. each winding is connected to half the mains voltage. The
motor is then adjusted optimally to the (operating) pump and gene-
rates very little noise apart from a very low power consumption – for
label AAA –, as the windings are connected to half the mains voltage
during operation. The motor features a thermal winding cover (bi-
metal) to prevent overheating.
Operation:
815_58300000003806_ara_en_e.doc – 30.01.12
Technical specifications:
or
Designation
Nominal voltage
Frequency
Resistor
Delivery height
Delivery capacity
Start:
Starting current
Operating current
Value
Unit
230–240
V
50
Hz
Ω
Ha approx. 44–57
HI approx. 50–55
Ω
3.9–4.1
m
25–30
l/min
2.4
A
0.31
A
Seite 29 von 67